Fluke
  Home - Product  


 
RY-4300D 2M E1/Datacom Transmission Analyzers

    RY-4300D E1/Datacom tester,2M E1/Datacom Transmission Analyzers is mainly used for measuring of the error rate of data communication and for the analysis of line fault and causes, and very suitable for the parameter measurement and routine maintenance testing of 2M system, N¡Á64K communication channels.
 



 RY-4300D Series E1/Datacom tester,2M Datacom Transmission Analyzers can be used to test the digital channels with 2Mbit/s interfaces and with V.24/V.28/RS232, V.35, V.36, RS449, X.21, RS485, EIA530, EIA530A, and equidirectional G.703 CO 64kbit/s interfaces.
¡ô Major Features

 ¡¤ LCD large-screen display, 320*240 lattice, backlight, LED indicator
 ¡¤ Hand held, auto configuration
 ¡¤ Multi-task operation at one time
 ¡¤ Store 20 test results and 9 test configurations, with power-off memories
 ¡¤ PC operation, store, analysis, print
 ¡¤ Programmable timer
 ¡¤ Alarm and histogram analysis
 ¡¤ Software updating

¡ô Major Functions

For 2Mbit/s:

 ¡¤ Service-interrupted error testing

 ¡¤ Online error testing

 ¡¤ Framed and unframed signals generation and reception

 ¡¤ 2Mbit/s unframed error performance testing

 ¡¤ 2Mbit/s framed N¡Á64kbit/s channel error testing

 ¡¤ Bit error, coding error, frame error, CRC error and E bit error testing

 ¡¤ Signal loss alarm, AIS alarm, framed remote alarm, multi-framed remote alarm, out-of-frame, and pattern loss alarm

 ¡¤ Frequency offset testing

 ¡¤ Line signal level and frequency testing

 ¡¤ Voice channel signal level and frequency testing

 ¡¤ Pattern slip testing

 ¡¤ Clock slip testing

 ¡¤ Straightforward signaling

 ¡¤ Audio frequency testing

 ¡¤ Loop circuit delay testing

 ¡¤ Automatic protection switching time testing (APS)

 ¡¤ Clock bias function

 ¡¤ Sound monitoring

 ¡¤ Duplex 2Mbit/s detecting and monitoring

 ¡¤ Signal state display. Voice channel content display. Voice channel busy indication

 ¡¤ Alarm and error histogram analysis

 ¡¤ Time slot content analysis, drop and insert signal on each time slot

 ¡¤ Framed content analysis

 ¡¤ G.703 module analysis

 ¡¤ G. 821/G. 826/M. 2100 error analysis

 ¡¤ Multi error and alarm inserting

 ¡¤ Three input modes (terminating, bridging and monitoring)

 ¡¤ Three clock options (internal, external and picking-up);

For Datacom:

 ¡¤ V.24/RS232/V.28, V.35, V.36, X.21, RS-449, RS-485, RS422, EIA-530, EIA-530A datacom testing

 ¡¤ SYNCH and ASYNCH testing

 ¡¤ DTE and DCE emulation

 ¡¤ Bit code testing

 ¡¤ Pattern slip testing

 ¡¤ Signal loss alarm

 ¡¤ Line signal level and frequency testing

 ¡¤ Loop delay testing

 ¡¤ Automatic protection switching time testing(APS)

 ¡¤ G.821, M2100 service interrupt error testing


For co-directional 64Kbit/s:

 ¡¤ Service interrupt error testing

 ¡¤ Bit code testing

 ¡¤ Pattern slip testing

 ¡¤ Signal loss, AIS alarm

 ¡¤ Line signal frequency testing

 ¡¤ Loop delay testing

 ¡¤ Automatic protection switching time testing(APS)

 ¡¤ G.821, M.2100 error testing

¡ô Technical Index

¡¤2M Technical Index

 (1) Signal input rate: 2048kbit/s¡À100ppm£¨G.703 requirement¡À50PPM£©

 (2) Signal coding: HDB3, AMI.

 (3) Input jitter tolerance: Up to the requirement of Figure 10.1.


Fig.10.1 Input Jitter Tolerance



 (4) Input balance response: Attenuation complies with the law of square root of frequency, and is within the range of 0 to 6dB at 1024 kHz.

 (5) Input Impedance

  (5.1) Unbalance terminating: 75¦¸

    Balance terminating: 120¦¸.

    Reflection loss >18dB within 50Hz¡«3100kHz.

  (5.2) Unbalance bridging: >750¦¸

    Balance bridging: >1200¦¸

  (5.3) Unbalance monitoring: 75¦¸, 26dB gain

    Balance monitoring: 120¦¸, 26dB gain

    Reflection loss >18dB within 50Hz¡«3100kHz.

 (6) Signal structure

  (6.1) Non-frame structure

  (6.2) Frame structure: PCM30, PCM31, PCM30CRC, PCM31CRC

    Frame structure complies with the requirement of G. 704.

 (7) Testing pattern: 26-1¡¢29-1¡¢211-1¡¢215-1¡¢220-1¡¢223-1, and artificial code

 (8) Impedance of output interface:

  (8.1) Non-balance 75¦¸, up to G. 703

  (8.2) Balance 120¦¸, up to G. 703.

 (9) External clock input

  (9.1) Signal form: HDB3, NRZ

  (9.2) Balance terminating resistance: 120¦¸

    Unbalance terminating resistance: 75¦¸.

    Balance bridging resistance: >1200¦¸

    Unbalance bridging resistance: >750¦¸.

 (10) Error code insertion: None, single, or ratio 10-1 ~ 10-7.

¡¤Co-directional 64k Technical Index

 (1) Signal input rate: 64 kbit/s¡À100ppm£¨G.703 requirement¡À100PPM£©

 (2) Input impedance: Balance 120¦¸, up to G.703

 (3) Input jitter tolerance: Up to G.823.

 (4) Impedance of output interface: Balance 120¦¸, up to G.703

 (5) Testing pattern:26-1¡¢29-1¡¢211-1¡¢215-1¡¢220-1¡¢223-1, and artificial code
Input Impedance

¡¤Datacom Index

 (1) Data interface type: V.24, V.35, V.36, X.21, RS-449, RS-485, EIA-530 and EIA-530A.

 (2) Generator

  (2.1) SYNCH mode

    Clock source: Internal or external clock

    Phase relation between clock and data: co-direction or reverse direction.

    Rate: 1.2£¬2.4£¬4.8£¬9.6£¬14.4£¬19.2£¬38.4£¬48£¬56(kbps)£»N¡Á64kbps£¨N=1¡«32£©

    Error: ¡À15ppm£¨ppm: parts per million£©

  (2.2) ASYNCH mode

    Rate: 50£¬75£¬110£¬150£¬200£¬300£¬600£¬1200£¬2400£¬3600£¬4800£¬7200£¬9600£»14.4k£¬19.2k£¬38.4k£¬57.6k£¨bps£©

    Data structure: Word length: 5£¬6£¬7£¬8£¨bits£©£»Stop bit: 1£¬2£¨bits£©£»

    Odd-even check: odd, even, 1, 0, none

  (2.3) Error code insertion: None, single, or ratio 10-1 ~ 10-7.

 (3) Receiver

  (3.1) SYNCH mode

    Clock source: Internal or external clock

    Phase relation between receive clock and receive data: Equidirection or reverse direction.

    Clock Rate: 2048kbps at a maximum

  (3.2) ASYNCH mode

    The rate and data are the same as those of the generator.

 (4) Testing pattern: 26-1¡¢29-1¡¢211-1¡¢215-1¡¢220-1¡¢223-1, and artificial code

¡ô Other Parameters

 ¡¤Power supply

  (1) Special power adapter

    Input: AC220V 50Hz

    Output: DC 9V 1A

  (2) Internal rechargeable battery

    4000mAh, 6V nickel-hydrogen rechargeable battery

    Working time: 8 hours

    Charging: 8 hours at power-off state, and 12 hours at power-on state.

 ¡¤Dimension and weight

  L¡ÁW¡ÁH: 200¡Á160¡Á42mm

  Weight: 950g

 ¡¤Ambient parameters

  Operation temperature: 0¡«40¡æ

  Storage Temperature: -30¡«+70¡æ

  Humidity: 5%¡«90%, non-condensing

¡ô Standard Configuration

No. Item Qty
1 GQ-4300D Series 2M Transmission Analyzers 1 set
Attached files
2 User's manual 1 pc
3 Software disc 1 pc
Attached accessories
4 75¦¸ Coaxial testing line 1 pc
5 BNC-L9 Testing line
CESHIYI
2 pcs
6 RS232 serial line 1 pc
7 Special testing cable of data communication¢ñ£¨V.24£¬RS-485£¬EIA-530£¬EIA-530A£© 1 pc
8 Special testing cable of data communication¢ò£¨RS-449£¬V.36£© 1 pc
9 Special testing cable of data communication ¢ó£¨X.21£© 1 pc
10 Special testing cable of data communication ¢ô£¨V.35£© 1 pc
11 G.703 CO special testing cable£¨64Kb/s coaxial interface£© 1 pc
12 Power adapter 1 pc
13 Data self-loop head 1 pc
14 Switch cable 1 pc
15 Handy-case 1 pc
16 Serial printing line£¨optional£© 1 pc

 

Product

Signal Level Meters 

Optical Power Meters  

Optical Light Sources 

Pentype Visual Fault Locator 

OTDR Testing 

Optical Multimeter  

RF Power Meters  

ADSL Testing 

2M/ E1 /Datacom Testing 

Insertion Loss&Return Loss Test Station 

Cable-Antenna Analyzers 

Fusion splicer  

Search Ruiyan
Resources Products
 
Find Resources

Home  |  About Us  |  Contact Us  |  Guangdong ICP No. 10024664 © 2005 - 2010 Ruiyan Corporation